DOMUS VENTILATION

CLIMATE HOUSE
WESTERN INDUSTRIAL ESTATE
CAERPHILLY
MID GLAMORGAN CF83 1NA

Tel: 03443 715523
Fax:

Company Logo

Suppliers of: Ventilation Ducting Ventilation Ducts Extractor Fans Bathroom Fans Kitchen Fans MVHR Mechanical Ventilation Heat Recovery MEV Mechanical Extract Ventilation

Domus Ventilation is a manufacturer of market-leading ventilation systems that save energy and improve indoor air quality. Established over 30 years ago, and now part of the Genuit Group, Domus Ventilation manufactures high quality and solution based ventilation products for the domestic and light commercial building industry from its state-of-the-art production facilities in South Wales. The company provides differentiated ventilation solutions, transforming the way developers, contractors, installers, home owners and distributors meet Building Regulations Parts F & L and emerging environmental standards. 

Useful Resources:

Main Product Ranges:

Fan Range:

The range includes award winning, high performing and energy efficient mechanical extract ventilation appliances and fans that are suitable for a wide variety of domestic applications and dwelling sizes.

Mechanical Ventilation with Heat Recovery (MVHR):

  • Ideal for new build
  • Continuous supply and extract ventilation incorporating heat recovery – for whole house applications

Mechanical Extract Ventilation (MEV):

  • System 3 in Approved Document F of the Building Regulations
  • Centralised ventilation unit that continuously extracts waste air

Decentralised Mechanical Extract Ventilation (dMEV):

  • System 3 in Approved Document F of the Building Regulations
  • dMEV fans continuously extract the waste air at both low trickle or boost speeds

In-Line / Axial / Centrifugal Extract Fans:

  • Domus Extract fans remove condensation and moist air and include options ideal for new build and refurbishment applications
  • NEW to the range are Sapphire fans – Designed to complement internal decor with extremely quiet performance.

House Packs:

  • Suitable for multi-floor, single-floor and apartment configurations
  • Over-the-counter full ventilation system

Fan Ancillaries & Controls:

Domus has a wide range of Accessories and Controls to use with our vast rage of ventilation solutions. These include:

  • Extract Fan fitting & Fixing kits
  • Extract Fan Control Options
  • MVHR Accessories / Filters / Duct Kits
  • Condensation Drain Kits
  • MEV Air Supply
  • Sapphire Fan Fascia
  • Spotvent Ceiling Light Grille

Domus Ducting:

Our range of Domus ducting offers a high quality solution for domestic & commercial applications.

  • Ducting Kits
  • Rectangular / Round / Thermal Ducting
  • Flexible / Semi-Rigid / Acoustic Ducting
  • Internal / External Grilles
  • Fire Prevention Solutions
  • Domus Adapt / Domus Radial Ducting Systems

Further Technical information is available to download from the BPi download library or from the Manufacturer’s own website.

 

 

 

AIR BRICK Adaptors
AIR BRICK Cowls
AIR BRICK Ducting
AIR BRICK Grilles Louvre
AIR BRICKS .
AIR BRICKS BS 493:1995
AIR BRICKS Ducted Cavity Liner
AIR BRICKS Ducted BS 493
AIR BRICKS Steel
AIR BRICKS Steel Low Resistance
AIR BRICKS Steel Non-Combustible Approved Document B (Fire Safety)
AIR BRICKS Ventilation
AIR CONDITIONING SYSTEM Ventilators Heat Exchange
AIR DIFFUSERS .
AIR DIFFUSERS Ceiling
AIR DUCT Fixings
AIR FILTERS Heat Exchange Ventilator Combined
AIR GRILLES Extract
AIR RECOVERY House Ventilation
AIR TREATMENT Equipment
AIR VALVES .
BRACKETS Tube
CABLE TRUNKING Accessories
CAVITY WALL Sleeves Fire Protection
CLIMATE CONTROL Air Handling Systems
CONDENSATE TRAPS Extractor Fan Systems
COOKER HOOD Ducting Kits Extraction Ducting
COOKER HOODS Extracting
COWLS Ventilator
DOOR Ventilators
DOOR Ventilators Slot
DUCT ATTENUATORS Sound Absorbing
DUCT CONNECTORS Intumescent
DUCT FLOW CONTROLS
DUCT FLOW CONTROLS Flow Control Plenums
DUCT FLOW CONTROLS Flow Control Plenums For Architectural Grilles
DUCT INSULATION EN 1366-1 EN 13163 -1
DUCT PIPES Plastic
DUCT SILENCERS Rectangular
DUCT SILENCERS Sound Absorbing
DUCTING Acoustic
DUCTING Aluminium
DUCTING Complete Systems
DUCTING Flat
DUCTING Flexible
DUCTING Flexible Thermally Insulated
DUCTING Insulated
DUCTING Low Profile
DUCTING Pre-Insulated
DUCTING Radial
DUCTING Rectangular
DUCTING Rigid
DUCTING Rigid PVC Purpose Made Bespoke
DUCTING Smoke Exhaust
DUCTING Tee Pieces and Connectors
DUCTING Utilities
EXTRACTOR FANS Automatic
EXTRACTOR FANS Automatic Shutter
EXTRACTOR FANS Axial Flow
EXTRACTOR FANS Bathroom
EXTRACTOR FANS Bathroom Ducted
EXTRACTOR FANS Bathroom IPX4
EXTRACTOR FANS Building Regs Regulations Document F
EXTRACTOR FANS Ceiling
EXTRACTOR FANS Ceiling Light and Ventilation Illuminating
EXTRACTOR FANS Centrifugal
EXTRACTOR FANS Chrome
EXTRACTOR FANS Combined Light
EXTRACTOR FANS Condensation Control
EXTRACTOR FANS Continuous Background Ventilation
EXTRACTOR FANS Continuous Mechanical Extract Ventilation dMEV Fans
EXTRACTOR FANS Energy Saving
EXTRACTOR FANS Energy Saving Low Energy
EXTRACTOR FANS Energy Saving Low Energy Low Voltage
EXTRACTOR FANS External
EXTRACTOR FANS Fire Shutter Combined
EXTRACTOR FANS Humidity Sensing / Activated Humidistat Controlled
EXTRACTOR FANS In-Duct
EXTRACTOR FANS In-Line
EXTRACTOR FANS Intermittent Extract Ventilation
EXTRACTOR FANS Interval Timed
EXTRACTOR FANS IPX2
EXTRACTOR FANS IPX3
EXTRACTOR FANS IPX4
EXTRACTOR FANS Kitchen
EXTRACTOR FANS Low Noise
EXTRACTOR FANS Multi-Point Central Extract Units
EXTRACTOR FANS Multi-Room
EXTRACTOR FANS PIR Sensing Movement Activated
EXTRACTOR FANS Roof Mounted
EXTRACTOR FANS Shower
EXTRACTOR FANS Timed
EXTRACTOR FANS Toilet
EXTRACTOR FANS Utility Room
EXTRACTOR FANS Wall Cavity Mounting
EXTRACTOR FANS Window
FAN CONTROLLERS Automatic
FAN CONTROLLERS Condensation Control
FAN CONTROLLERS Humidistat
FAN CONTROLLERS Humidity Sensing Remote
FAN CONTROLLERS Time Delay Units
FAN COVER GRILLES Wall Mounted
FANS Air Recirculation
FANS Axial
FANS Axial Continuous Operation
FANS Bathroom
FANS Bathroom Extra Low Voltage
FANS Bathroom Extra Low Voltage S.E.L.V.
FANS BS EN 60335
FANS BSRIA Tested
FANS Ceiling
FANS Centrifugal
FANS Chrome
FANS Condensation Control Automatic
FANS Delayed Switch
FANS Domestic
FANS Domestic Low Voltage Low Energy
FANS Domestic Ventilation
FANS Duct
FANS Duct Ceiling Mounted
FANS Energy Saving
FANS Exhaust .See Also EXTRACTOR FANS:
FANS External
FANS Heat Recovery
FANS Heat Recovery Whole House
FANS Humidity Control
FANS In-Line Duct
FANS In-Line Duct Axial
FANS In-Line Duct Centrifugal
FANS ISO 3741:1988
FANS Kitemarked
FANS Light Combined
FANS Multi Room In Line Duct
FANS Plug In
FANS Pull-Cord
FANS Safety Extra Low Voltage SELV
FANS Shower
FANS Timer
FANS Ventilation Systems
FANS W.C.
FANS Wall
FANS Window
FIRE COLLARS EN 1366-3: 2009
FIRE COLLARS Intumescent
FIRE PENETRATION SEALS BS 476:1987 Part 20
FIRE PENETRATION SEALS BS 1366-3:2009
FIRE PROTECTION For Ducts
FIRE PROTECTION For Ducts Approved Doc B
FIRE PROTECTION For Ducts BS 476:1987 Part 20
FIRE PROTECTION For Ducts EN 1366-3
FIRE PROTECTION For Ducts Fire Resisting Sleeves
FIRE PROTECTION For Ducts Fire Stops BS EN 1366-3:2009
FIRE SEALS BS 476:1987 Part 20
FIRE SEALS Intumescent
FIRE SEALS Intumescent BS 476:1987 Part 20
FIRE SEALS Intumescent EN 1366-3
FIRE SLEEVES BSEN 1363-1 BSEN 1366-3
FIRE SLEEVES Ducting Applications
FIRE SLEEVES Intumescent
GRILLES Air See Also VENTILATION GRILLES
HEAT EXCHANGERS Whole House Ventilation Systems
HEAT RECOVERY SYSTEMS See Also VENTILATION SYSTEMS: Heat Recovery
HOSE Air
HOSE Plastic
KITCHEN VENTILATION .
KITCHEN VENTILATION Extractor Fans
LAVATORY Ventilation
LAVATORY Ventilation Delay Switch
LOUVRES AND SCREENS PVC-u
LOUVRES AND SCREENS Ventilating / Ventilation
PIPE Suspension Systems
PIPE Suspension Systems Ventilation
PIPE BRACKETS
PIPE BRACKETS Suspended
PLENUM BOXES Integral Flow Control Device
REGISTERS .
REGISTERS Ceiling Ventilation
REGISTERS Cill Ventilation
REGISTERS Wall Ventilation
REPLACEMENT FRESH AIR INLETS Non-Mechanical Passive Natural Ventilation
ROOF Terminals
ROOF VENTILATION Cowl
ROOF VENTILATION Cowl High Rise
ROOFING SLATES Roof Weathering Slates
ROOFING SLATES Roof Weathering Slates Ventilation Slates
SEALANT Tapes
SEALANT Tapes Self-Adhesive
SEALANTS Mastic
SEALANTS Mastic: By Colours: White
SEALANTS Mastic: by Composition: Acrylic
SEALANTS Mastic: by Special Function: Ductwork
SEALANTS Mastic: by Special Function: Intumescent
SEALANTS Mastic: by Special Function: Intumescent Acoustic
SOIL PIPES and FITTINGS Vent Terminals
TAPES Duct Tape
TUMBLE DRYER Ventilating Kits Extraction Ducting
VENTILATION Airbricks
VENTILATION Bathroom Powered
VENTILATION Bathroom Powered Ducted
VENTILATION Cavity Wall (Powered)
VENTILATION Combined Light
VENTILATION Condensation Traps
VENTILATION Continuous
VENTILATION Cooker Hood Kits
VENTILATION Cowls
VENTILATION Delayed Switch
VENTILATION Diffusers
VENTILATION Fire Control
VENTILATION Outlets
VENTILATION Outlets Air Terminals Internal Wall Room
VENTILATION Outlets Airbrick
VENTILATION Outlets Airbrick Adaptors
VENTILATION Outlets Bull Nose
VENTILATION Outlets Cowled
VENTILATION Outlets Stainless Steel
VENTILATION Registers
VENTILATION Tumble Dryer Kits
VENTILATION WC (Powered)
VENTILATION Window
VENTILATION Window Kits
VENTILATION DUCTING Acoustic
VENTILATION DUCTING Aluminium
VENTILATION DUCTING Cooker Hood
VENTILATION DUCTING DIN 4102 B1
VENTILATION DUCTING Fire Resistant Ducts
VENTILATION DUCTING Flat Channel
VENTILATION DUCTING Flexible Hose
VENTILATION DUCTING Heat Recovery Systems
VENTILATION DUCTING Kits
VENTILATION DUCTING Low Profile
VENTILATION DUCTING Push to Fit
VENTILATION DUCTING PVC
VENTILATION DUCTING Rigid Duct Systems
VENTILATION DUCTING Silencer Incorporated
VENTILATION DUCTING Tumble Dryer
VENTILATION DUCTING UL94 V2
VENTILATION DUCTING Wall
VENTILATION DUCTING Whole House Systems
VENTILATION GRILLES .
VENTILATION GRILLES Duct Outlet
VENTILATION GRILLES Insect Screen Incorporated
VENTILATION GRILLES Plastic
VENTILATION GRILLES Square Mesh
VENTILATION GRILLES Stainless Steel
VENTILATION GRILLES Supply
VENTILATION GRILLES Wall
VENTILATION LOUVRES Fixed Domestic
VENTILATION SYSTEMS Central Extract Domestic
VENTILATION SYSTEMS Design
VENTILATION SYSTEMS Domestic Ceiling Terminals
VENTILATION SYSTEMS Domestic Condensation Control
VENTILATION SYSTEMS Domestic Heat Exchange
VENTILATION SYSTEMS Domestic Mechanical Continuous Supply and Extract MEV
VENTILATION SYSTEMS Domestic Thermal Transfer Systems
VENTILATION SYSTEMS Heat Recovery
VENTILATION SYSTEMS Heat Recovery Domestic
VENTILATION SYSTEMS Heat Recovery Domestic MVHR Whole House Systems
VENTILATION SYSTEMS Heat Recovery Whole House
VENTILATION SYSTEMS Heat Recovery Whole House MVHR Exchanger Combined
VENTILATION SYSTEMS Heat Recovery Whole House MVHR Mechanical Ventilation Heat Recovery
VENTILATION SYSTEMS Heat Recovery Whole House SAP Appendix Q Listed
VENTILATION SYSTEMS Internal Systems Powered
VENTILATION SYSTEMS Manufacturing and Design Purpose Made Bespoke Systems
VENTILATION SYSTEMS Mechanical NOx Filtration Incorporated
VENTILATION SYSTEMS Mechanical Extract Ventilation MEV / dMEV
VENTILATION SYSTEMS Mechanical Extract Ventilation Single Room dMEV
VENTILATION SYSTEMS Multi-Room Systems
VENTILATION SYSTEMS Natural Louvred
VENTILATION SYSTEMS Roof and Wall
VENTILATION SYSTEMS Safety Extra Low Voltage SELV
VENTILATION SYSTEMS Whole House Building Regs Document F
VENTILATION SYSTEMS Whole House Building Regs Part L Compliant
VENTILATION SYSTEMS Whole House Central Extract Centralised Balanced
VENTILATION SYSTEMS Whole House Centralised Design Service
VENTILATION TERMINALS Mechanical Extract
VENTILATION TERMINALS Natural
VENTILATION TERMINALS Roof Mounting
VENTILATION UNITS Continuous Mechanical Extract Systems MEV System 3 Approved Doc F
VENTILATION UNITS Heat Recovery
VENTILATION UNITS Heat Recovery Social Housing
VENTILATION UNITS MVHR Units
VENTILATOR Cowls
VENTILATORS Door
VENTILATORS Heat Recovery
VENTILATORS Plinth
VENTILATORS Wall
VENTILATORS Worktop
BLUEBRAIN Mechanical Ventilation Controller
D-SERIES Extractor Fans
DOMUS Ventilation Ducting
DOMUS ADAPT Ducting Systems
DOMUS CLASSIC Extractor Fans
DOMUS CMX Mechanical Extract Ventilation Systems
DOMUS CMX-MULTI Mechanical Extract Ventilation Systems MEV
DOMUS CMX-S Mechanical Extract Ventilation Systems MEV
DOMUS CURZON Extractor Fans
DOMUS ENERGEX Thermoactuators
DOMUS HRX-aQ Mechanical Ventilation with Heat Recovery MVHR
DOMUS HRX2D Mechanical Ventilation with Heat Recovery MVHR
DOMUS HRXE-AURA Mechanical Ventilation with Heat Recovery MVHR
DOMUS HRXE-HERA Mechanical Ventilation with Heat Recovery MVHR
DOMUS KITCHENAIRE Extractor Fans
DOMUS MAYFAIR Extractor Fans
DOMUS RADIAL Whole House Ventilation
DOMUS SAPPHIRE Decentralised Mechanical Extract Ventilation dMEV
DOMUS SOLIS AIR BRICK Metal Airbricks
DOMUS SPOTVENT Shower Ceiling Lights
DOMUS SUPERTUBE Ducting
DOMUS THERMAL Duct Insulation
DOMUS TRIPLEVENT Power Circuit
DOMUS VITALIS In Line Mixed Flow Duct Fans
EASIPIPE Ducting
FIREBRAKE Fire Sleeves
FLOW CONTROL PLENUM Duct Flow Controls
MEGADUCT Ducting
MICROBAN Rigid Duct Attenuator
NOX FILT NOx Filtering Ventilation Ducting Systems
NOX-FILT NOx Filtering Ventilation Ducting Systems
SAPPHIRE Domestic Extractor Fan
SAPPHIRE GREEN LINE Extractor Fans

Domus Ventilation has expanded our thermal ducting offer

November 2026

Introduction of a new all-in-one insulated ducting range gives installers and specifiers greater choice when selecting the right ducting solution for individual residential ventilation projects. Introduced alongside the existing Domus Thermal insulation range, the new system combines the ventilation duct and thermal insulation within one lightweight, ready-to-install component. Its distinctive clamping mechanism creates a secure connection without the need for separate sealant or tape, helping to make installation straightforward, particularly in lofts, ceiling voids and other restricted spaces.

The new Domus Thermal range has also been developed using eco-efficient materials and is fully compliant with relevant Building Regulations requirements for insulated ventilation ductwork. Available in rectangular formats including 204 x 60mm and 220 x 90mm, the range incorporates coordinated straight lengths together with 45° and 90° horizontal and vertical bends. This enables installers to create continuous insulated duct runs using matched components.

The addition gives customers a choice of two different approaches to thermal ducting. Domus Ventilation’s established Domus Thermal system uses purpose-designed insulation fitted around its rigid ductwork, while the new all-in-one range integrates the duct and insulation into a single component. This allows installers and specifiers to select the solution best suited to the requirements of the individual project, taking into account factors such as installation method, available space, duct route and site conditions.

Both solutions are designed for ventilation ductwork passing through unheated spaces and voids, where insufficient insulation can allow condensation to form. They are particularly suited to intake and exhaust ductwork serving Mechanical Ventilation with Heat Recovery (MVHR) systems.

In an MVHR installation, warm, moisture-laden extract air may travel through ductwork located in a cold loft or roof space. Conversely, cold incoming air may be carried through ducts situated within the heated part of a property. In either case, inadequate insulation can result in condensation forming within or on the outside of the ductwork. Effective thermal insulation helps limit heat transfer across the duct wall, reducing the risk of condensation and helping to protect both the ventilation installation and surrounding building materials.

“Different projects can place very different demands on the ductwork installation, which is why choice is important,” states Paul Williams, Product Manager at Domus Ventilation. “Rather than there being one solution for every application, our aim is to give installers and specifiers the flexibility to select the right product for the right project. Together, the two ranges strengthen the thermal ducting options available from Domus and make it easier to specify a solution appropriate to the individual installation.”

Correct ductwork selection and installation are fundamental to ventilation system performance. Excessive resistance, air leakage, poorly formed bends or unsuitable components can prevent a ventilation appliance from delivering its intended airflow rates, while potentially increasing noise and energy consumption.

The two Domus Thermal ranges form part of Domus Ventilation’s extensive portfolio of residential ventilation ducting and ancillaries, which includes rigid rectangular and circular ducting, semi-rigid radial systems, flexible and acoustic ducting, air valves, grilles, external terminals and associated installation components.

By Paul Williams, Domus Ventilation Product Manager

Domus Continuous or intermittent extract? Choosing the right fan for the job

September 2026

For installers, replacing or specifying a domestic extract fan can appear to be a relatively straightforward task. However, the choice between an intermittent extract fan and decentralised mechanical extract ventilation (dMEV), should not be based solely on price, familiarity or whether the new fan fits the existing opening. Both technologies have an important role to play, but they operate in fundamentally different ways. Selecting the right option requires an understanding of the property, the ventilation strategy and how the occupants are likely to use the system.

What is the difference?

An intermittent extract fan operates for a limited period, typically when activated by a light switch, pull cord, presence detector or humidistat. Depending on the model, a timer may keep the fan running after the room has been vacated. This provides a relatively high rate of extraction when activities such as showering, bathing or cooking create moisture and pollutants. Once the fan switches off, however, mechanical extraction from that room stops.

A dMEV fan is designed to operate continuously. It extracts air at a low background rate and moves to a higher boost rate when additional ventilation is required. Rather than waiting for moisture or pollutants to build up before extraction begins, it provides ongoing air movement throughout the day and night. It is important not to view dMEV simply as an intermittent fan that has been left switched on. It forms part of a continuous mechanical extract ventilation strategy, with background and boost airflow rates that must be appropriate for the dwelling.

Approved Document F recognises intermittent extract with background ventilators and continuous mechanical extract as different approaches to ventilating a home. Whichever strategy is selected, its purpose is to provide adequate ventilation while maintaining indoor air quality.

When can an intermittent fan be the right choice?

Intermittent fans remain an established and appropriate solution for many applications, particularly in existing homes.

A like-for-like replacement may be suitable where an existing intermittent ventilation strategy is performing effectively, the dwelling has adequate background ventilation and there is no evidence of persistent condensation, mould or excessive humidity.

They can also provide a straightforward solution for individual bathrooms, toilets, utility rooms and kitchens, especially where the fan discharges directly through an external wall. Models are available with different methods of control. Domus Ventilation, for example, offers 100mm and 150mm axial bathroom and kitchen fans, including standard, timer, pull-cord and humidistat-controlled variants allowing you to match the fan to the room and its likely use.

However, an intermittent fan is only effective when it operates for long enough and delivers the required airflow. A fan connected to the bathroom light may not run adequately if an occupant takes a quick shower during daylight hours and does not switch on the light. The same issue can arise if the overrun period is too short or the fan is isolated because the occupant considers it noisy.

When should dMEV be considered?

dMEV is particularly relevant to new build homes, where greater airtightness makes a planned and dependable ventilation strategy essential. It may also be suitable for refurbishment projects and existing properties where there are persistent moisture problems or where relying on occupants to activate an intermittent fan is unlikely to provide consistent ventilation.

Because a dMEV fan runs continuously at a low rate, moisture and pollutants are extracted as they are generated. The fan can then boost when greater extraction is needed as is the case with the Domus dMEV-NICO which comes with an integral monitoring device enabling automatic operation in response to occupant activity. This can help avoid the cycle in which humidity builds up while an intermittent fan is off and is then expected to clear the room in a relatively short operating period.

Continuous operation can also be valuable in rented and social housing, where landlords and property managers require a ventilation solution that does not depend entirely upon occupant behaviour.

Look beyond the fan itself

Choosing between dMEV and intermittent extract is only part of the installer’s job. Even a correctly selected fan will underperform if the rest of the installation prevents it from delivering its intended airflow.

The duct route is a key consideration. An axial fan may be suitable for a short, direct discharge through an external wall, but longer or more restrictive duct runs can create resistance that reduces airflow. Bends, crushed flexible ducting, poorly fitted connectors and obstructive external grilles can all affect performance. Installers should therefore check the complete air path rather than relying solely on the airflow stated on the fan packaging. The most powerful fan is not necessarily the right fan if its performance cannot be achieved in the installed arrangement.

Replacement air is equally important. An extract fan cannot remove air effectively from a sealed room unless air can enter from elsewhere. Background ventilators, suitable door undercuts and an unobstructed route for air to move through the dwelling are integral to the ventilation strategy.

Noise must also be considered. A fan that achieves the required airflow but is intrusive in operation may be switched off or isolated by the occupants. Where a continuous fan is installed, quiet operation at its normal background setting is especially important because the product is intended to run throughout the day and night.

Do not replace a fan without checking the strategy

When attending an existing property, it can be tempting to remove the old fan and install the nearest equivalent. Before doing so, installers should consider why the fan is being replaced.

If it has simply reached the end of its service life and the existing ventilation arrangement is otherwise effective, a suitable intermittent replacement may be entirely appropriate. If the call-out has been prompted by condensation, mould or repeated complaints about humidity, replacing the fan like for like without investigating the wider causes may achieve very little.

The problem could be an inadequate run-on time, insufficient airflow, unsuitable ducting, a lack of background ventilation or an occupant who rarely activates the fan. In these circumstances, dMEV may offer a more reliable solution, but it still needs to be selected and commissioned as part of a properly considered approach.

There will also be properties where neither an individual intermittent fan nor a single dMEV unit is the complete answer. Larger new build and extensively refurbished homes may require a whole-house system, such as centralised mechanical extract ventilation or mechanical ventilation with heat recovery.

The key is to avoid treating ventilation as a collection of isolated fans. Each product should contribute to the movement of air through the dwelling, from the supply of fresh air to habitable rooms through to the extraction of moisture and pollutants from wet rooms.

For electrical installers, the decision is therefore not simply whether dMEV is better than intermittent extract. It is about identifying which solution suits the property, the room and the intended ventilation strategy. Intermittent fans continue to provide an effective and cost-conscious answer in many applications, while dMEV offers dependable continuous extraction where a more consistent approach is required.

Making that assessment before installation will help deliver better performance, reduce the risk of callbacks and, most importantly, provide occupants with ventilation that works in practice rather than only on paper.

By Paul Williams, Domus Ventilation Product Manager

List all press releases