HONEYWELL GENT

NOVAR SYSTEMS LTD
CARLTON PARK
NARBOROUGH
LEICESTERSHIRE LE19 0LF

Tel: 0203 409 1779
Fax:

Company Logo

These files are provided by the manufacturer. While Building Products Index takes every care to ensure the information is correct and up to date, we cannot be held liable for any out of date or incorrect information in them. You should check with the supplier before specifying or purchasing products.

HONEYWELL GENT: Analogue Addressable Manual Call Points - Analogue Addressable Manual Call Points
Every manual call point is continuously monitored ensuring a trigger is responded to in less than one second system wide.The range includes options for glass and resettable elements and lift-up protective covers.An environmentally protected (EP) version with Ingress protection rating IP67 is also available, complete with resettable element, protective cover and backbox.Features and benefits:Resettable elements.Lift up protective covers.Weatherproof version (IP67) suitable for external areas.Up to 200 per loop.Integral short-circuit isolator.Surface or semi-flush options.Certified to EN 54 part 11 and 17. Manual call points

Published [30/03/2026]

HONEYWELL GENT: COMPACT-PLUS - Fire Alarm Panel
The Compact Plus 2 loop panel accommodates up to 200 devices including advanced fire sensors, interfaces, call points, alarm sounders, and visual alarms. It features integrated 24-hour standby capacity and provides a clear, back-lit LCD display indicating Fire or Fault location. The innovative 8-line x 40 character display with push-button keypad ensures simple operation. Fire plans can be tailored to precisely meet site requirements.The panel is fully compatible with Honeywell Gent’s S-Quad range – a combined Multi-Sensor range with speech, sounder, and EN54-23 visual alarm devices in one intelligent unit.Features and benefits:Integral EN54-4 PSU and battery standby for 24 hours.Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires.PC based commissioning tools allow complex fire plans to be configured.Advanced loop card technology allows for system status monitoring and diagnostics.Extended event log using flash memory card.The control panel has a simple user interface with LCD screen providing accurate information in an emergency.Flexible programming options are available at the panel.All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required.Loop length up to 2 km.High powered loop capable of support large numbers of Sounders and EN5 4-23 VAD's.Compatible with Honeywell Gent Self Testing Sensor Technology.Capable of connecting to Cloud Based Connected Life Safety Systems (CLSS) management system.In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events.Network capacity of up to 200 control panels.PC based Graphics user interface (GUI) available.EN 54-2 and 4 certified. Fire alarm panels

Published [30/03/2026]

HONEYWELL GENT: Fire Alarm Interfaces - Loop Powered Interfaces
Vigilon can accommodate a high quantity of loop connected interface units offering flexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fire, to linking with other emergency management systems such as sprinklers or security systems.Loop powered interfaces offer a cost effective solution with each device individually addressed increasing the overall management capability of the FD&A system.Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.Features and benefits:Loop powered devices reducing cost of installation and maintenance.Individual addresses to maximise information and flexible cause and effect.Each device with EN 54-17 short circuit handling for enhanced system integrity.Comprehensive range of functionality in each device variant to simplify system design.Complete range of mounting enclosures and accessories.Options to connect conventional fire detectors such as flame and beam detectors.Certified to EN 54-17 and EN 54-18. Fire alarm input and output modules

Published [30/03/2026]

HONEYWELL GENT: S-Cubed Sounders and VADS - Loop Powered Alarm Sounders and VADS
S-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN 54-23 certified low current consumption, high performance visual alarms. Combined with flexible configuration from the fire control panels, this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.Features and benefits:Very low power consumption means that the Vigilon system offers more high performance sounders and VADs on the loop than any other manufacturer.Each loop can support up to 200 voice sounders, 100 visual alarm devices (VADs) and up to 70 combined sounder VADs.Alarm tones full synchronised across all loops on a control panel.EN 54-23 VADs with adjustable light coverage matching the sounder output.Environmentally Protected (EP) range with an IP66 rating.Four voice phrases and a bell tone available as standard.Voice and tone modes can be freely configured within the same sounder.3 different alarm tones selectable for Alert, Evacuate and other emergency tones.Active background monitoring of sounder and VAD circuits.Short circuit isolator in each device.SOFT Addressing technique, no need for DIP switch, EPROMS or programming at time of installation.Adjust the sounder volume via the commissioning tool, the panel or the HandiLink infrared remote control.EN54-3, EN54-17 & EN54-23 certified depending on which variant is selected. Fire alarm sounders

Published [30/03/2026]

HONEYWELL GENT: S-Quad Analogue Addressable Smoke, Heat, Multi- Sensors - Smoke and Heat Sensors
Intelligent analogue addressable fire sensors combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.Features and benefits:Complete range of sensors with combinations of advanced sensing technologies including heat, dual angle optical scatter and carbon monoxide (CO).Combined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting fires.Each sensor has LPCB certified sensitivity states that suit certain environments/ applications and may be programmed for different times of the day if required.Short circuit isolator in each device.SOFT Addressing technique, no need for DIP switch, EPROMS or programming at time of installation.Configurable input/ output connection for remote indicator or supervisory input fully synchronised sound patterns via the control panel.Sensor sounders have adjustable sound level and tones to match system sounders.Sounder element monitoring and over-load protection to ensure operation even in event of cable fault.Sound output synchronised and compatible with S-Quad range of EN 54-23 VADs.EN54 Certified. Smoke and heat multi-sensor detectors

Published [30/03/2026]

HONEYWELL GENT: S-Quad Analogue Addressable Smoke, Heat, Multi- Sensors - Smoke and Heat Sensors
Intelligent analogue addressable fire sensors combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.Features and benefits:Complete range of sensors with combinations of advanced sensing technologies including heat, dual angle optical scatter and carbon monoxide (CO).Combined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting fires.Each sensor has LPCB certified sensitivity states that suit certain environments/ applications and may be programmed for different times of the day if required.Short circuit isolator in each device.SOFT Addressing technique, no need for DIP switch, EPROMS or programming at time of installation.Configurable input/ output connection for remote indicator or supervisory input fully synchronised sound patterns via the control panel.Sensor sounders have adjustable sound level and tones to match system sounders.Sounder element monitoring and over-load protection to ensure operation even in event of cable fault.Sound output synchronised and compatible with S-Quad range of EN 54-23 VADs.EN54 Certified. Smoke and heat multi-sensor detectors

Published [30/03/2026]

HONEYWELL GENT: S-Quad Beam Detection - Fire Alarm Beam Detection
Gent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.Powered and controlled via the 2 core loop, the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting, this ensures the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.The Gent loop powered beam is certified to EN 54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.Features and benefits:S-Quad Beam pairs are loop powered supporting 16 pairs per loop.Each beam can be set to one of six sensitivity states to provide a best fit for individual applications.The beam provides increased resilience to interference from the sun and other light sources.Remote key switch provides test facility at ground level without the need to gain access to beams mounted in high areas.The beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioning.Optimum sensitivity is maintained by automatic gain setting triggered at the beam during alignment.The optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning required.The S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software.Short circuit isolator in each device.SOFT Addressing technique, no need for DIP switch, EPROMS or programming at time of installation.Beam length from 2m to 100m.EN5412 & 17 Certified. Optical beam smoke detectors

Published [30/03/2026]

HONEYWELL GENT: S-Quad Multi-Sensor with Sounders/ VADs - Smoke and Heat Sensors
S-Quad’s Multi-sensor with integrated sounder and VAD combines renowned advanced sensing technology with state of the art visual alarms. The only practical solution meeting the demands of detection and the performance needed to meet the EN 54 part 23 standard.Features and benefits:Sensor and alarm in one device reduces installation time and cost. Built-in high intensity VAD helps alert occupants in noisy environments as well as the hard of hearing.Meets all the requirements of the Equality Act 2010.Compatible with the S-Cubed wall mounted VAD.State of the art, high efficiency visual alarm technology.Advanced power management that increases loop capacity and integrity.Range of devices and power settings to suit widest range of building applications.Light output that allows devices to be sited at standard smoke and heat detector spacings.Synchronised flash rate across the whole control panel avoiding risk of induced seizures.VAD can operate independently of the sounder if required.Meets the requirements of BS 5839 part 1 relating to sensitivity to epilepsy. Smoke and heat multi-sensor detectors

Published [30/03/2026]

HONEYWELL GENT: S-Quad Multi-Sensor with Sounders/ VADs - Smoke and Heat Sensors
S-Quad’s Multi-sensor with integrated sounder and VAD combines renowned advanced sensing technology with state of the art visual alarms. The only practical solution meeting the demands of detection and the performance needed to meet the EN 54 part 23 standard.Features and benefits:Sensor and alarm in one device reduces installation time and cost. Built-in high intensity VAD helps alert occupants in noisy environments as well as the hard of hearing.Meets all the requirements of the Equality Act 2010.Compatible with the S-Cubed wall mounted VAD.State of the art, high efficiency visual alarm technology.Advanced power management that increases loop capacity and integrity.Range of devices and power settings to suit widest range of building applications.Light output that allows devices to be sited at standard smoke and heat detector spacings.Synchronised flash rate across the whole control panel avoiding risk of induced seizures.VAD can operate independently of the sounder if required.Meets the requirements of BS 5839 part 1 relating to sensitivity to epilepsy. Smoke and heat multi-sensor detectors

Published [30/03/2026]

HONEYWELL GENT: S-Quad Self Testing Sensors - Smoke and Heat Sensors
S-Quad industry changing S4T Series – self-test multi-sensors with sounder, voice, and VAD variants.The integrated self-test functionality enables automated testing of both the heat and optical sensors. The patented testing method involves heating the heat-sensing thermistor and generating real aerosol (smoke) to test the optical sensor. An internal fan disperses the aerosol from the detection chamber through the smoke entry points and into the surrounding environment. This simulates a realistic fire scenario and verifies that the smoke entry points remain unobstructed and capable of detecting actual smoke, whilst also checking that the detection device has not been covered.Each unit includes Bluetooth Low Energy (BLE) functionality. When BLE is activated, the device acts as a beacon, enabling detection by mobile applications such as the CLSS app. BLE capabilities support device identification, verification of device details, and confirmation of proximity during visual inspections.The S4T is a redesigned detector device featuring an IP21-rated external moulding, a new detector chamber design, and a dual microprocessor PCB. The updated architecture enhances smoke detection performance and increases voice storage capacity.Features and benefits:Available in a large range of multi-sensor, Part-23 VAD and sounder/ voice options.Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device (phone or tablet). No more impact on building occupiers.Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber.Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked.Flexible testing options allow the engineer to test in different ways – single device, detection zone, loop(s), panel(s).Allows up to six devices to be tested at once per loop and any number of loops can be tested simultaneously, making the functional testing incredibly fast.Device testing is fast enough to allow up to four functional tests to be performed per year for the lifespan of the device.Eliminates all access issues when detector testing, ensuring 100% functional testing is achieved.Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated.Any fires detected outside of the devices performing self-test will stop the self-test process and operate the fire systems cause and effect.Allows the engineer to easily locate the detector using the App and BLE to check the device number, label, zone description and detector type.Allows simple device updates to be performed through the App, including the correction of inaccurate device labels and loop mapping.The app and BLE handshake verifies that the engineer has been within visual inspection range.Optional Inspection prompt LEDs on the device let the engineer know what self-test devices need to be visually inspected and will automatically turn off when the visual inspection is complete.Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms.Test fire LED option in the App allows the fire LED to be tested (a pending BS 5839-1 testing requirement). This feature can additionally confirm that they are inspecting the correct device.The CLSS App allows the engineer to simulate a fire and test the cause and effect logic.The CLSS App also allows the cause and effect to be triggered through a successful self-test operation, allowing a witness test to be performed using real smoke.EN54 Certified and Designed to meet the requirements in full of section 43.3.5, 42.2.6 and 43.3.7 Smoke and heat multi-sensor detectors

Published [30/03/2026]

HONEYWELL GENT: Vigilon Plus - Fire Alarm Panel
Vigilon Plus Control Panels are available in four or six loop variants, each accommodating up to 200 devices per loop, including advanced fire sensors, interfaces, call points, alarm sounders, and visual alarms. The four loop panels are available with integrated 24-hour standby, while the six loop panel offers full 72-hour standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure, with copper or fibre optic connections available (Vigilon four and six loop panels only).Vigilon’s back-lit LCD display presents clear indication of fire or fault location, and the control panel’s innovative 8-line x 40 character display with push-button keypad is simple to use. Fire plans can be tailored to precisely meet site requirements.Vigilon’s software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gent’s innovative S-Quad range – a combined Multi-Sensor range with speech, sounder and EN 54-23 Visual Alarm devices in one intelligent unit.The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop, the repeat panel offers a cost-effective solution with minimal cabling and installation requirements. Repeat panels are supplied with their own 72-hour power supply and standby batteries.Features and benefits:Integral EN 54-4 PSU and battery standby for 24 hours (four loop).Integral EN 54-4 PSU for 72 hours with external batteries (six loop).Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires.PC based commissioning tools allow complex fire plans to be configured.Advanced loop card technology allows for system status monitoring and diagnostics.Loop length up to 2 km.High powered loop capable of support large numbers of Sounders and EN 54-23 VAD's.Compatible with Honeywell Gent Self Testing Sensor Technology.Capable of connecting to Cloud Based Connected Life Safety Systems (CLSS) management system.Extended event log using flash memory card.The control panel has a simple user interface with LCD screen providing accurate information in an emergency.Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management.Flexible programming options are available at the panel.All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required.In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events.PC based Graphics user interface (GUI) available.EN 54-2 and 4 Certified. Fire alarm panels

Published [30/03/2026]