ELAND CABLES
Suppliers of: Electrical Cables, Tri-rated Cables, Industrial Cables, Armoured Cables, Power Cables, Bespoke Cables, Control Cables, Railway Cables and Cable Accessories.
Eland Cables supplies electrical cables and accessories to industries worldwide, covering cables for fixed wiring, low and medium voltage power, DNO’s, control and instrumentation applications. It’s not just the Building and Construction industry we work with - we cover EV charging, Renewables, Data centres and automation and process control for large commercial and industrial operations.
We deliver a tailored service on a global scale, combining our range of cables with a range of services designed to support your project and ensure smooth integration within your timelines and goals. We work extensively within the Building and Construction industry, with a portfolio of cables meeting British, European and International standards.
For technical datasheets, cable tools including our cable calculator, and more information on our products, services and testing capabilities, please visit the website.
Quick Links
- Watch our ‘Introduction to Eland Cables’ video
- Read how we work with our customers in our Case Studies
- ESG and Sustainability – View our commitments and policies
- View the Construction Products Regulation (CPR) compliance page
Read on for more information on why we are the cable specialists that the building and construction industry trust for quality products, exceptional service and technical expertise.
Our range includes aluminium wire armoured and steel wire armoured cables that can be installed in concrete and suited to total immersion in water. Some of our fixed wiring cables such as the 6491B, SWA BS6724 or Twin and Earth BS7211 624-B are available with a LSZH (Low Smoke Zero Halogen) oversheath, making them compliant with installations where life and equipment needs additional protection in the event of fire.
Medium Voltage (MV) cable solutions
We provide a range of MV cable solutions, as a specialist MV cable supplier our standard medium voltage cable portfolio contains cable with single and 3-core copper or aluminium conductors. As an expert in the sector we can design and supply bespoke MV cable products developed for your specific applications. With our specialist MV test facility included as part of The Cable Lab®, we undertake a range of tests on cables of rated voltage of 3.3/6.6kV upwards.
Distribution Network Operators (DNOs) and Construction
We supply a wide range of utility-approved cables and overhead lines to the transmission, distribution and power networks industry around the world. Our extensive work with the DNOs means we’re able to supply a broad range of DNO approved cables from stock and on short manufacturing lead times for larger projects. Our cables hold approvals for several UK-based electric utilities.
We give our customers peace of mind, knowing the cable you install will meet the demands of your application is key, we’re uncompromising in our commitment to quality and compliance. Our cables are subject to testing in our ISO 17025 accredited facility, The Cable Lab® to ensure they meet the performance demands and regulatory requirements expected.
Third-party accredited cables are available, including BASEC approved and LPCB certified. We also hold the BSI Cable Testing Verification Kitemark.
Construction Products Regulation (CPR)
You’ll be familiar with CPR but we can provide expert guidance where it relates to electrical cables. We are fully compliant with the Construction Products Regulation, and can support your fixed installations with classified cables, including meeting the recent changes to the Irish standard IS10101 and the voluntary guidance of BS6701 (data and communications cables).
Our technical experts sit on national standards committees at the heart of the CPR adoption and compliance process. If you would like more information on how this legislation affects you, please see our CPR infographic or email cpr@elandcables.com
When you need expert advice, our highly qualified technical experts and industry specialists can provide support from specification through to installation, with guidance on regulatory matters, industry best practice, and cable suitability.
If you need your cables in a hurry, our extensive stockholding of cables means we supply the UK, Ireland, and parts of continental Europe with Next-Day delivery from stock as standard. Using our FORS accredited fleet we can ensure timely delivery, where and when you need your cable order.
Our drivers are trained in cable handling and your order is packaged to arrive in optimum condition. Our transport team can provide instant PODs with drivers tracked every step of the way. Working within your project timelines, we can create a tailored delivery schedule that works for you.
Environmental, Social, and Governance (ESG) & Sustainability
Like you, we take ESG and Sustainability seriously. When it concerns our people, our communities, the environment, or our governance, our focus is simple – to make a positive impact and sustainable contribution whenever we can.
To view how we lead by example visit the website to discover more. You’ll also be able to see key policies and learn about how we work with our supply chain, our approach to diversity, inclusion and wellbeing.
Eland Cables - how public perceptions of Renewable Energy are changing
Results and findings from YouGov survey commissioned by Eland Cables: July 2026.
Renewable energy has largely won public support in Britain. But as the UK's energy transition gathers pace, expectations are changing.
To better understand how people view renewable energy and the infrastructure required to support it, we commissioned YouGov to survey the British public on their attitudes towards the transition. The results reveal a clear trend: support for renewable energy remains strong, but confidence in its ability to deliver affordable, reliable and secure energy is less certain.
Key findings
64% of Britons have a positive view of renewable energy.
44% believe the transition to renewable energy is happening too slowly.
51% doubt renewables will provide affordable energy costs over the next decade.
51% are unconvinced renewables can generate enough electricity to meet future UK demand.
75% support offshore wind developments, while 65% support onshore wind and 61% support large-scale solar projects.
Support remains positive even when projects are proposed closer to home, suggesting scrutiny is not the same as opposition.
Young adults are the strongest supporters of renewable energy and the most confident in its ability to deliver long-term outcomes.
The findings suggest that renewable energy is increasingly being judged not as an emerging technology, but as critical national infrastructure. As a result, public expectations are shifting from questions of acceptance to questions of performance.
For those working across the energy sector, this presents an important challenge. Building support remains important, but building confidence in the infrastructure, networks and systems that underpin the energy transition will be essential to its long-term success.
Visit https://www.elandcables.com/ to download our report, From Support to Scrutiny, to explore the full findings and what they mean for the future of the UK's energy transition.
Eland Cables - BS7671 Amendment 4 - An Overview
The IET and BSI have confirmed the publication of Amendment 4 to BS 7671:2018, introducing key changes to the Wiring Regulations that will shape electrical installations from 2026 onwards. Published on 15 April 2026, the amendment takes effect immediately, with Amendment 3:2024 withdrawn on 15 October 2026.
The update reflects the accelerating adoption of renewable energy, battery storage and digital infrastructure, while placing a stronger emphasis on electrical fire safety and system resilience. Several of the new provisions extend both the scope and depth of installation requirements, with practical implications across design, product selection, and compliance.
What did Amendment 3:2024 introduce?
Amendment 3:2024 to BS 7671 focused on strengthening protection against fire, electric shock and electrical faults, particularly in domestic and similar installations. Key updates included an expanded emphasis on Arc Fault Detection Devices (AFDDs), refinements to requirements for surge protection devices (SPDs), and clarifications around RCD selection and coordination.
The amendment also supported the growing use of low‑carbon technologies by building on earlier requirements for EV charging equipment, prosumer installations and renewable energy systems.
Key changes introduced by Amendment 4
Stationary Secondary Batteries (New Chapter 57)
Chapter 57 introduces dedicated requirements for stationary secondary battery systems, reflecting their rapid and widespread adoption across modern electrical installations. This chapter sets out requirements for the design, selection and installation of battery energy storage systems (BESS), recognising their growing use alongside PV installations, EV charging infrastructure and onsite energy storage. The regulations address key safety considerations associated with high‑energy systems, including fire risk management, ventilation and protection against electrical and thermal hazards.
Specific attention is given to installation location, with guidance that limits or discourages battery installations in roof spaces, where fire detection, containment and emergency intervention can be more challenging. Requirements also cover means of isolation, protection against overcurrent and short‑circuit faults, and the control of thermal effects during both normal operation and fault conditions. Ventilation provisions are included to prevent the accumulation of heat or gases, depending on battery technology. The chapter adopts a risk‑based approach, allowing system design to account for factors such as battery chemistry, enclosure type and proximity to occupied areas, while establishing a consistent baseline for electrical and fire safety.
Power over Ethernet (PoE) (Section 716)
Section 716 sets out requirements for Power over Ethernet (PoE) installations where data cables are used to carry extra-low voltage DC at relatively high power levels in addition to data signals. The regulations recognise that higher PoE power classes can lead to increased temperature rise within cables, particularly where multiple cables are grouped or installed in enclosed containment systems. As a result, the section places emphasis on current‑carrying capacity, derating and installation conditions, ensuring that cables are not operated beyond their thermal limits. Protection against mechanical damage is also addressed, by applying the general wiring-system principles of BS7671 to PoE cabling. The requirements aim to ensure that PoE systems are designed and installed with the same level of thermal and safety as traditional power circuits, while acknowledging their unique characteristics. Section 716 reinforces the need for coordination between electrical and ICT design to maintain safety, performance and reliability.
Functional Earthing and Bonding (Section 545)
Section 545 includes specific requirements for functional earthing and functional equipotential bonding, particularly for ICT systems, smart technologies and data‑driven equipment. The regulations distinguish functional earthing, which supports system performance and electromagnetic compatibility, from protective earthing, which is intended primarily for safety against electric shock. This distinction helps reduced unwanted interference without compromising protective measures or fauly protection. The section provides guidance on when functional earthing is required, how it should be connected, and how it should be coordinated with the overall earthing arrangement of the installation. Functional equipotential bonding is emphasised as a means of reducing electromagnetic disturbance across interconnected equipment. These requirements reflect the growing complexity of modern installations, where reliable operation depends not only on safety measures but also on signal stability, noise reduction and system interoperability across multiple technologies.
Medical Locations (Section 710)
Section 710 contains updated requirements for electrical installations in medical locations, where continuity of supply and fault protection are critical to patient safety particularly in Group 1 and Group 2 locations. The regulations reinforce the role of supplementary protective equipotential bonding in reducing touch voltages under fault conditions, particularly in patient environments. A key update is the introduction of new schedules for recording the measured resistance of supplementary bonding connections, supporting consistent verification and traceability of test results throughout the life of the installation. These records form part of the ongoing inspection and testing regime, ensuring that safety measures remain effective after commissioning. The section continues to differentiate requirements based on the medical location classification, including Group 1 and Group 2 areas, and aligns bonding, earthing and protective measures with the operational risks present. Overall, the updates strengthen procedural clarity and support a lifecycle approach to electrical safety in healthcare environments.
Energy Efficiency (Chapter 81)
Chapter 81 introduces a structured framework for considering energy efficiency in low‑voltage electrical installations, extending the scope of electrical design beyond safety and functionality. Rather than mandating specific technologies, the chapter focuses on assessment and informed decision‑making, encouraging designers and operators to evaluate energy losses and efficiency opportunities within an installation. This includes consideration of conductor losses, equipment selection and operational practices. The framework can be applied to new installations, extensions or significant alterations, allowing energy efficiency to be considered proportionately and in line with project objectives. This chapter aligns electrical installation practice with wider sustainability and decarbonisation goals, supporting improved transparency around energy performance. By embedding energy efficiency into the regulatory structure, the chapter formalises its role as a core design consideration alongside protection, reliability and compliance.
Amendment 4: the impact
Amendment 4 reflects a wider shift towards electrification, digitalisation and decentralised energy, increasing the need for careful product selection where fire performance, thermal behaviour and reliability are critical. This is particularly relevant for installations involving energy storage, PoE and higher‑risk environments.
These changes also sit alongside the Construction Products Regulation, reinforcing the importance of ensuring that products used in fixed electrical installations are appropriately classified, documented and verified as projects move towards their 2026 compliance timelines.
Copies of BS7671 Amendment 4 can be purchased from the IET website.












