Masonry Window Sills: Why Most Sill Details Fail and How the Type U Tray Solves It

February 2026

Summary: What the Type U Undersill Tray Delivers

Function: How the Type U Undersill Tray delivers it
Sill angle & alignment: Variable support dimensions plus front alignment lip
Damp prevention: Permanent in-situ dpc barrier beneath sill masonry
Sill-end water control: Large stop ends prevent lateral discharge at jambs
Reveal integration: Stop ends provide upstand for Cavicloser connection
Cavity drainage: Transient drainage holes and Pyramid Caviweep outlets
Thermal cold bridge reduction Insulation bonded to rear upstand isolates sill from inner skin

A masonry sill is one of the most exposed elements of any external wall. Every rain event drives water directly onto it. Yet the sill itself is rarely where the failure happens; the failure happens where the sill meets the reveal. That junction, where horizontal sill masonry meets vertical reveal masonry, is the most susceptible point in the entire window opening for water volumes and water ingress. And it is the one detail that is most commonly overlooked at the design stage.
The Three Jobs a Masonry Sill Must Do, and the One Most Builders Miss

Most designers and builders approach a masonry sill with two requirements in mind:

1. External appearance and weathering performance
The sill must provide the visual presence the designer requires, and its profile should deflect rainwater outward and away from the wall face.

2. Cavity closure without damp or thermal bridging The sill must close the cavity horizontally without creating a pathway for moisture or cold to track inward toward the inner skin.
Both are well understood. The third requirement is not:

3. Effective integration with the reveal closing arrangement
Where the sill masonry meets the reveal masonry at each jamb, there must be a continuous, integrated damp-arresting connection. Without it, water that collects at the sill ends, exactly where volumes are highest, has a direct route into the wall.

Read more about rotational movement here

Addressing all three requirements together is what separates a sill detail that performs from one that eventually leaks.
Why Masonry Sill Formation Creates an Inherent Risk

Forming a masonry sill in brick, tile or stone requires each unit to be bedded at an angle, typically sloping forward to shed water. That angled bedding position must be achieved without creating a rigid structural connection to the inner skin, unless that connection incorporates an integral DPC barrier.

Without a purpose-designed DPC element beneath the sill, any moisture that permeates through the sill masonry, and all masonry is porous to some degree, has a direct pathway toward the inner skin. Add the vulnerability of the sill-end-to-reveal junction, and the result is a detail that is doing three difficult jobs with no dedicated product to support it.
The Type U Undersill Tray: One Product, Three Functions

The Type U Undersill Tray is a profiled dpc tray designed specifically for masonry sill formation in cavity walls. Rather than treating the sill as a structural element that happens to sit near a cavity, it treats the sill as a cavity wall detail, with all the damp-arresting, thermal and integration requirements that imply.

It performs three distinct functions simultaneously:

As formwork during construction
The Type U tray is bedded into position first, before sill masonry commences. It has two variable-dimension support areas on each tray. By selecting the dimensions required at design stage, the designer can specify the finished angle and appearance of the sill. The front projecting lip acts as an alignment guide so the front face of each sill unit is uniform and straight. Once the sill masonry has been constructed over the tray and fully cured, a grooved detachment line allows the front lip to be cleanly removed, leaving only the finished sill masonry projecting.

As a permanent dpc barrier
Once the front lip is removed, the remainder of the Type U tray stays in place, permanently enveloped within the wall. It acts as a continuous damp course beneath the sill, preventing moisture from tracking inward through the wall construction. Water that permeates through the sill masonry above can drain via transient drainage holes in the tray bed and via Pyramid Caviweeps positioned at tray bed level, directing it safely out through the face of the wall.

As an integrated reveal connection
At each end of the tray, large stop ends bear against the face of the reveal masonry. These stop ends prevent water from discharging sideways at the most vulnerable point, the sill-to-jamb junction, and crucially provide an upstand against which the vertical reveal Cavicloser can integrate directly. The Cavicloser is typically notched and extended below the finished sill level to complete the continuous damp barrier around the full perimeter of the opening.
Thermal Performance: Combining Damp Control With Cold Bridge Reduction

The Type U tray’s rear upstand, the element that supports the sill at the chosen angle, also provides a surface onto which insulation can be bonded. In cavity walls where thermal performance is a priority, insulation fixed to the back upstand of the Type U tray isolates the masonry sill from the inner skin, reducing thermal cold bridging at the sill position.