HALFEN STEEL BALCONY CONNECTOR

Starting with the pre-assembled fixings installed within the reinforcement cage and attached to the formwork. After the formwork is struck four fixing points are left visible. Threaded rods are then inserted into these holes to allow the fixing of the bracket assembly. The rods, when inserted fully, are then followed by an insulation/separation pad and then the SBC bracket itself. Vertical adjustment is achieved via slots in the bracket with toothed patches providing the vertical slip resistance. Once final position achieved, then toothed washers and bolts attached to fix the bracket in position. The brickwork/facade can then be built up around the bracket providing minimal delay to other services and the overall project speed. Horizontal adjustment is achieved via slots in the front of the bracket allowing for maximum adjustment and flexibility of balcony installation.