TOXFREE® PLUS RZ1-K (AS+), the fire-resistant cable for emergency circuits

May 2026

TOXFREE® PLUS RZ1-K (AS+), the fire-resistant cable for emergency circuits

TOXFREE® PLUS RZ1-K (AS+) 0.6/1kV is a power cable specially designed to transmit electrical energy in the extreme conditions that occur in a prolonged fire, ensuring the supply to emergency equipment such as signalling, smoke extractors, acoustic alarms, water pumps, etc.

A HIGH-SAFETY (AS+) FIRE-RESISTANT CABLE
In addition to the properties of a TOXFREE® High Safety (AS) cable: no fire propagation and no fire propagation, TOXFREE® PLUS RZ1-K (AS+) 0.6/1kV fire resistant cables must comply with a structure that allows the electrical circuits that are essential for safeguarding people’s lives to remain operative at all times, facilitating their evacuation.
TOXFREE® PLUS RZ1-K (AS+) 0.6/1kV fire resistant cables maintain power supply even under the extreme conditions of prolonged fire in direct contact with fire. In this way they maintain the integrity of the electrical circuits, guaranteeing the operation of emergency equipment (alarms, smoke extractors or forced ventilation, emergency signalling and lighting, water pumps, inert network, automatic opening of doors, video surveillance cameras, etc.).
TECHNICAL CHARACTERISTICS OF TOXFREE® PLUS RZ1-K (AS+)
The main feature of the cable is its ability to provide maximum safety in case of fire. On the more technical side, these are the main features provided by its design:
Flame and fire non-propagation
Flexible cable
Halogen free
Minimum service temperature: -40ºC
TECHNICAL ADVANTAGES OF A FIRE RESISTANT CABLE (AS+)
In this table you can see a comparative overview of the differences between a PVC cable, an LSZH cable and an AS+ cable:
Application PVC cables LSZH cables
(AS) Fire-resistant cables
(AS+)
High-Security Cables Industrial Public attendance
(hospitals, schools, airports, shopping centres) Emergency equipment
(smoke extractors, acoustic alarms, water pumps)
CPR classification Eca Cca, B2ca B2ca
High Security Cables No (AS) (AS+)
Smoke emission (*) High Low Low
Fire propagation (*) Yes No No
Emits toxic / corrosive substances (*) Yes No No
Transmits electrical energy during a prolonged fire No No Yes
Cover colours (1000V) Black Green Orange
Designation “V” Z1 Z1 (AS+)
Reference cables POWERFLEX® RV-K
TOXFREE® RZ1-K (AS)
TOXFREE® PLUS RZ1-K (AS+)

(*) In case of fire
INSTALLATIONS WHERE THE USE OF TOXFREE® PLUS RZ1-K (AS+) CABLE IS RECOMMENDED
Manufactured by Top Cable, it is especially recommended for emergency circuits in public places such as hospitals, airports, tunnels, undergrounds, data centres, offices, production plants, laboratories, etc.
• Industrial use.
• Public premises.
• Emergency circuits.
• Data Centres (DC) and other critical installations.
It can be installed in the open air, in conduits and/or buried in indoor and outdoor installations, both in single and multi-conductor versions.
WHERE TO BUY ORANGE FIRE-RESISTANT CABLES TOXFREE® PLUS RZ1-K (AS+)?
To buy TOXFREE® PLUS RZ1-K (AS+) fire-resistant cable on drums of various sizes, please see our sales conditions for Electrical Wholesalers and Distributors here. We can also connect you with your nearest Top Cable distributor.
Some of the most common cross-sections in immediate stock are as follows:
Cable Conductor cross-section
(mm2) Outer sheath colour
TOXFREE® PLUS RZ1-K (AS+) 1 x 2,5 Orange
TOXFREE® PLUS RZ1-K (AS+) 1 x 4 Orange
TOXFREE® PLUS RZ1-K (AS+) 1 x 6 Orange
TOXFREE® PLUS RZ1-K (AS+) 3G 1,5 Orange
TOXFREE® PLUS RZ1-K (AS+) 3G 2,5 Orange
TOXFREE® PLUS RZ1-K (AS+) 3G 4 Orange
TOXFREE® PLUS RZ1-K (AS+) 4G 1,5 Orange
TOXFREE® PLUS RZ1-K (AS+) 4G 2,5 Orange
TOXFREE® PLUS RZ1-K (AS+) 4G4 Orange
Most common TOP CABLE TOXFREE® PLUS RZ1-K (AS+) cable cross-sections in immediate stock
If you need to consult additional technical aspects of this cable, such as its maximum admissible current or voltage drop, please contact Top Cable.