SIKABIT BITUMINOUS ROOFING

WATCHMEAD
WELWYN GARDEN CITY
HERTFORDSHIRE AL7 1BQ

Tel: 01707 394444
Fax: 01772 255672

Company Logo

Suppliers of: Bituminous Roofing Membranes, torch-on roofing membranes, roof waterproofing membranes, flat roof membranes torch-on.

Building on Sika’s trusted expertise as a global leader in roofing solutions, SikaBit® complements the Liquid Applied Membranes and Single Ply Membranes in the Sika portfolio with a suite of advanced Bituminous Membranes, offered with the same high standards of technical support and customer service.

SikaBit® PRO BITUMINOUS MEMBRANES are designed to provide safer and secure roof waterproofing solutions. The systems includes flame free installation for compliance with Safe2torch guideline. Our roofing solutions comprise of all the elements needed with Sika® vapour control layers, adhesives, insulation, rooflights and roof drainage, all covered by the SikaBit® guarantee.

Useful Resources:

SikaBit Pro Membranes

Bituminous Cap Sheets

  • SikaBit® PRO SA-940 G:  4 mm elastomeric & plastomeric bituminous hybrid roof membrane, self-adhesive with a mineral granule finish, flexible at -25 °C
  • SikaBit® PRO T-940: 4 mm elastomeric & plastomeric bituminous hybrid roof membrane with a fleece finish, flexible at -25 °C
  • SikaBit® PRO T-940 G: 4 mm elastomeric & plastomeric bituminous hybrid roof membrane, torch applied, with a mineral granule finish, flexible at -15 °C

SikaBit ProMelt - Hot Melt Flat Roof System

SikaBit ProMelt is the latest addition to Sika’s Roofing portfolio of bituminous, single ply and cold applied liquid membranes. Predominately, this hot applied membrane is used for inverted cold flat roofing areas or podiums, walkways or balconies due to its non-tracking monolithic state. As a system, SikaBit ProMelt is BBA certified for the durability of the design life of the roof, showcasing its outstanding durability. Another benefit to this technology, is that it can be installed all year round, and is backed with the support from Sika’s roofing application and technical teams.

  • SikaBit® Hot Melt 50/70 -  Monolithic rubberised bitumen membrane for roof waterproofing
  • SikaBit® Roof F-50 UK - Hot Melt Reinforcing Polyester Fleece
  • SikaBit® Roof Access Layer UK - SBS Modified bituminous protection membrane
  • SikaBit® Roof Insulated Outlet

Bituminous Base Sheet

SikaBit® PRO SA-730 is an SBS modified, bituminous, self-adhesive, roof waterproofing membrane. It is reinforced with a dimensionally stable non-woven polyester inlay which gives high stability and good mechanical properties. The underside has a removable liner over the adhesive compound for easy application. Top surface finish: polyethylene film. Thickness: ~3,0 mm

Bituminous Air and Vapour Control Layer

S-Vap® HD SA is an elastomeric self-adhesive vapour control layer and carrier membrane made of polymer modified bitumen with an aluminium composite and glass combination inlay.  The top suface has a sanded finish. 

Green Roof Membranes

SikaBit® Pro T-240 RT is an APP modified bituminous, torch applied, roof waterproofing membrane containing an anti-root additive. It is reinforced with a dimensionally stable non-woven polyester inlay. The underside has a polyethylene burn-off film for easy application. It it is as protection generally as an anti-root barrier over SikaBit® roofing membranes. Top surface finish: polyethylene film. Thickness: ~4,0 mm

Further technical information is available to download from the BPi PDF Download Library or directly from the Manufacturer’s own website.

BITUMEN Membranes Liquid
BITUMEN Membranes Preformed
BITUMEN Rubber Emulsion
GEOTEXTILES Geosynthetic Barriers Tree Root Barriers
INSULATION BOARDS Built-Up Roofing
INSULATION BOARDS Built-Up Roofing Hot Applied Bitumen Applications
INSULATION BOARDS Roofing Applications
INSULATION BOARDS Roofing Applications Built-Up Systems
INSULATION BOARDS Roofing Applications Extruded Polystyrene Foam (XPS)
INSULATION BOARDS Roofing Applications Inverted Roof
MEMBRANES Bitumen Rubber
MEMBRANES Bitumen Rubber Self-Adhesive
MEMBRANES Mineral Coated Torch Applied
MEMBRANES Reinforced Bitumen Hot Bonded Torch-On Applications
MEMBRANES Root Barriers
MEMBRANES Vapour Control Layers Torch-On Applications
MEMBRANES Waterproofing: Torch-On Applications
MEMBRANES LIQUID APPLIED Hot Melt
MEMBRANES LIQUID APPLIED Hot Melt Hot Applied Bitumen
MEMBRANES LIQUID APPLIED Hot Melt Hot Applied Bitumen AGREMENT CERTIFICATE HOLDERS
MEMBRANES LIQUID APPLIED Hot Melt Protection Sheets
ROOFING MEMBRANES .See Also ROOFING UNDERLAYS: PITCHED ROOF MEMBRANES
ROOFING MEMBRANES AGREMENT CERTIFICATE HOLDERS
ROOFING MEMBRANES Ballasted Systems
ROOFING MEMBRANES Built-Up Systems
ROOFING MEMBRANES Flat Roof
ROOFING MEMBRANES Green Roof
ROOFING MEMBRANES Green Roof Root Penetration Barrier
ROOFING MEMBRANES Green Roof Root Penetration Barrier EN 13948
ROOFING MEMBRANES Hot Melt Bitumen
ROOFING MEMBRANES Hot Melt Bitumen AGREMENT CERTIFICATE HOLDERS
ROOFING MEMBRANES Internal Vapour Control Layers
ROOFING MEMBRANES Inverted Roof Systems
ROOFING MEMBRANES Inverted Roof Systems AGREMENT CERTIFICATE HOLDERS
ROOFING MEMBRANES Modified Reinforced Bitumen
ROOFING MEMBRANES Modified Reinforced Bitumen AGREMENT CERTIFICATE HOLDERS
ROOFING MEMBRANES Modified Reinforced Bitumen Anti-Root Additive Incorporated
ROOFING MEMBRANES Modified Reinforced Bitumen Composite Capsheets
ROOFING MEMBRANES Modified Reinforced Bitumen EN 13707 CE Marked
ROOFING MEMBRANES Modified Reinforced Bitumen Multilayer Capsheets
ROOFING MEMBRANES Modified Reinforced Bitumen Polymer Modified
ROOFING MEMBRANES Modified Reinforced Bitumen Self Adhesive
ROOFING MEMBRANES Modified Reinforced Bitumen Torch Applied
ROOFING MEMBRANES Modified Reinforced Bitumen Torch Applied Mineral Coated
ROOFING MEMBRANES Modified Reinforced Bitumen Torch Applied Safe2Torch Systems
ROOFING MEMBRANES Reinforced Bitumen Rubber Hot Applied Monolithic Membrane Systems
ROOFING MEMBRANES Roof Garden Systems
ROOFING MEMBRANES Self Adhesive
ROOFING MEMBRANES Waterproofing
ROOFING MEMBRANES Waterproofing AGREMENT CERTIFICATE HOLDERS
ROOFING MEMBRANES Waterproofing AVCL Air and Vapour Control Layers
ROOFING MEMBRANES Waterproofing Capsheets
ROOFING MEMBRANES Waterproofing EN 13707 CE Marked
ROOFING MEMBRANES Waterproofing Exposed Sheets UV Stabilised
ROOFING MEMBRANES Waterproofing Self Adhesive
ROOFING MEMBRANES Waterproofing Torch-On
ROOFING SHEETS Flexible Rolls: AGREMENT CERTIFICATE HOLDERS
ROOFING SHEETS Flexible Rolls: Modified Reinforced Bitumen
ROOFING SHEETS Flexible Rolls: Torch Applied
ROOFING SHEETS Flexible Rolls: Torch Applied AGREMENT CERTIFICATE HOLDERS
ROOFING SHEETS Flexible Rolls: Torch Applied Capsheets
ROOFING SHEETS Flexible Rolls: Torch Applied EN 13707 CE Marked
ROOFING SHEETS Flexible Rolls: Torch Applied Granular Mineral Surface UV Resistant
ROOFING SHEETS Green Roof
ROOFING SHEETS Green Roof Root Penetration Barrier
ROOFING SHEETS Green Roof Root Penetration Barrier EN 13948
ROOFING SYSTEMS Bituminous AGREMENT CERTIFICATE HOLDERS
ROOFING SYSTEMS Built-Up Systems
ROOFING SYSTEMS Built-Up Systems Hot Applied
ROOFING SYSTEMS Hot Melt
UNDERLININGS For Torch-On Roofing
S-LEAFGUARD Leafguards
SIKA IGOLFLEX Flexible Rubber/Bitumen Emulsion Coating & Primer
SIKABIT PRO Bituminous Waterproofing Membranes
SIKABIT PROMELT Hot Applied Butuminous Liquid Membranes
SIKATHERM Insulation Boards for Built-Up Roofing

SikaBit - Cyns Tavern, Little Hulton in Salford

January 2021

BACKGROUND

Cyns Tavern, is a traditional community pub located in the Little Hulton area of Salford. Since its construction in the 1970s it has maintained its popularity with local residents. The existing felt covering on an area of the roof had reached the end of its service life and in order to prevent further damage to the building fabric, the owner wanted to carry out a roof refurbishment.

The project provided an ideal opportunity for roofing contractor, LRL Roofing Solutions, to leverage the team’s experience in bituminous roofing systems and use the innovative, new SikaBit Safe2Torch system in a project for one of the company’s major customers, Forviva.
SikaBit Cyns Tavern project
REQUIREMENT

The pub is situated in a busy urban location, close to shops and residential properties, and the area of roof involved in the project adjoins the Little Hulton Civic Centre, so safety was top priority throughout.

The project specification called for an upgrade of the existing roof, using the latest hybrid bitumen technology. This was to be applied as an overlay onto the existing roof-build, in full compliance with NFRC (National Federation of Roofing Contractors) Safe2Torch Guidelines.

It was therefore, essential that the chosen system was compatible with the existing roof surface and could be installed safely within a short programme, whilst the pub remained open to business.

SIKABIT SOLUTION

In order to assess whether the roof was compatible with the Sika Bit’s Safe2Torch system, a detailed roof condition survey was carried out by the technical team. As a result of this the team developed a full specification for installation of a SikaBit Safe2Torch system onto the existing room.

The team at LRL Roofing solutions began by preparing the existing roof by retaining the existing felt and the air and vapour control layer. Sika’s Primer 610 spray adhesive was applied to the roof surface, followed by SikaBit SA 730; the fully self-adhered 3mm underlay that forms part of the complete SikaBit Safe2Torch system.

With the underlay in place across the roof area, LRL Roofing Solutions installed SikaBit T940 G torch-on cap sheet in all the Safe2Torch zones. The self-adhesive SikaBit SA 940G cap sheet was then installed in the torch exclusion zones, which included upstands and a 900mm area at either side of the roof where it adjoins neighbouring structures.

On one corner of the building, where the roof abuts a timber-clad structure, the installation team used Sika Liquid Plastics’ Decothane solid-applied liquid membrane in combination with the self-adhesive SikaBit system to provide a best practice solution with a joined up specification from a single supplier.

"The fully self-adhered underlay went down well, with great lap seals that enabled us to leave it overnight prior to installation of the cap sheet. We achieved an extremely consistent bleed from the self-adhered cap sheet, providing us with great confidence within the Safe2Torch element of the system. The SikaBit cap sheet was really easy to apply, and we found it more pliable than other bituminous membranes."
Contracts Manager at LRL Roofing Solutions, Mick Raistrick

SikaBit - Castlemead, London Borough of Southwalk

January 2021

Castlemead is a social housing block in the London Borough of Southwark, located in the busy Camberwell Road area. The vacant building was undergoing an internal refurbishment project, delivered by fit out specialist, Paragon, and as part of these works the main contractor brought in roofing specialist, Hambro Roofing, to carry out some repairs to the existing felt roof. It quickly became apparent that the existing roof surface had reached the end of its service life and actually required a full refurbishment

SikaBit Castlemead project
REQUIREMENT

The client wanted to use a Safe2Torch-compliant reinforced bitumen membrane (RBM) roofing system that could be installed as an overlay to the existing roof, providing a like-for-like appearance while upgrading the performance and service life of the existing roof covering. SikaBit’s best-of-both-world’s SBS and APAO hybrid bitumen technology provided the ideal solution to achieve consistency of specification while enhancing the roof build-up.

There was also a requirement to reduce the potential for standing water by introducing falls to the roof using a tapered insulation scheme to improve drainage and direct run-off water to existing drainage outlets.

SIKABIT SOLUTION

Hambro Roofing suggested to Paragon that the roof should be refurbished with a RBM overlay and proposed the SikaBit system for the project due to the flexibility and tensile strength benefits of the SBS elements combined with the hardwearing properties and UV stability of APAO.

Sikabit’s technical team visited site to carry out a roof condition survey and develop a full technical specification, which included the Safe2Torch SikaBit system and SikaTherm tapered insulation.

The Hambro Roofing team cleaned and prepared the existing roof surface before installing an SVAP HD SA self-adhesive air & vapour control layer (AVCL), which has been specifically developed using SBS bitumen technology, an aluminium layer and a self-adhesive backing to provide a torch-free element of the SikaBit system. The roof was then coated with Sika Primer 600 followed by installation of the tapered insulation scheme.


The SikaBit SA730 fully self-adhered underlay was then installed onto the insulation layer and the Hambro Roofing team installed the torch-on SikaBit T940 G cap sheeet in the Safe2Torch zones, before completing the project by installing SikaBit SA940 G self-adhesive cap sheet in all the torch exclusion zones.

The SikaBit system offered Hambro Roofing the flexibility required to address unforeseen challenges with the roof. During the project, the contractor discovered that there were operational hot water pipes running through a central wall at roof level. The Hambro Roofing team was able to box in the pipes and then dressed the SikaBit system to the boxed area, ensuring it was completely watertight.

To complete the roof installation, Hambro Roofing installed a new GRP trim around the fascia, concealing the change in curb heights prompted by the tapered insulation.

"We were extremely impressed with the SikaBit Safe2Torch system and how it performed on this project. Thanks to SikaBit’s hybrid technology we were able to apply the correct heat to achieve a perfect bleed in the Safe2Torch areas while the self-adhesive membrane provided the same high quality of finish in the exclusion zones, delivering a great finish across the whole roof area."
Mark Robinson, Contracts Manager at Hambro Roofing

List all press releases